Dedispec Colocation Solutions
On-premise hardware can become expensive and unpredictable, that's why Dedispec offers enterprise grade colocation at a fraction of the cost. Let us worry about what's behind your rack while you focus on scaling your business. Whether you need to colocate a single server, or an entire cage of racks, Dedispec has the space and infrastructure to support your businesses colocation needs.
Single Server Colocation
Ideal for a single server up to 2U rack units in size.
- Rack Space: 1U or 2U Dedicated Rack Space
- Power: 1A @ 208V Power Included
- Network: 1Gbps Network Port
- Bandwidth: 30TB Monthly Bandwidth
- IP Space: /30 IPv4 Included
- Location: Kansas City, MO
Single Server Colocation
Ideal for a single server up to 4U rack units in size.
- Rack Space: 3U or 4U Dedicated Rack Space
- Power: 1A @ 208V Power Included
- Network: 1Gbps Network Port
- Bandwidth: 30TB Monthly Bandwidth
- IP Space: /30 IPv4 Included
- Location: Kansas City, MO
Quarter Rack Colocation
Quarter rack space allowing you 10U of space for your equipment
- Rack Space: 10U Dedicated Rack Space
- Power: 5A @ 208V Power Included
- Network: 1Gbps Network Port
- Bandwidth: 100TB Monthly Bandwidth
- IP Space: /28 IPv4 Included
- Location: Kansas City, MO
Half Rack Colocation
Half rack space allowing you 21U of space for your equipment
- Rack Space: 21U Dedicated Rack Space
- Power: 10A @ 208V Power Included
- Network: 1Gbps Network Port
- Bandwidth: 200TB Monthly Bandwidth
- IP Space: /28 IPv4 Included
- Location: Kansas City, MO
Full Rack Colocation
Full private 42U locking cabinet with optional A+B power circuits.
- Rack Space: 42U Dedicated Rack Space
- Power: 20A @ 208V Power Included
- Network: 1Gbps Network Port
- Bandwidth: 1Gbps Monthly Bandwidth
- IP Space: /27 IPv4 Included
- Location: Kansas City, MO
Need Private Cages, Multiple Server Racks, or High Power Solutions?
Contact us with your colocation needs. Whether you need private locking cages, 400Gbit network ports, 13200V Primary Power, we have the infrastructure to handle your needs.
Explore the KC1 Data Center
⚡ Power Infrastructure
Power is available at 13200v, 480v, 477v, 208v and 110v AC
External wrap around bypasses on every UPS, isolation bypass on every ATS.
Fed at 13,200V from both the Avondale Substation (NE) and NKC Substation (S).
Dedicated breakers at NKC substation fed with dedicated primary power lines.
Priority utility handling given the same priority as government and emergency services.
2N backup generators sized to each utility feed with automatic ATS transfer.
Can supply power to your cabinet from 4 separate utility feeds.
Power available at 13200v, 480v, 477v, 208v and 110v AC.
Enough fuel onsite to run generators for 72+ hours with emergency refueling contracts.
2N Eaton UPS systems covered by Eaton service contracts with spare parts inventory onsite.